◆ Maximum conductor size 30mm
◆ Dimension: 195 x 64 x 30mm
◆ 3-1/2 digit LCD display with maximum reading of 2000
◆ Low battery indication
◆ AC Current: 0.1A to 600A, ±(2.0% of rdg + 5 dgts)
◆ AC Current (Auto): 0.1A to 400A
◆ AC Voltage: 0.1V to 600V, ±(1.5% of rdg + 5 dgts)
◆ DC Voltage: 0.1V to 600V, ±(1.0% of rdg + 2 dgts)
◆ Resistance: 0.1Ω to 200Ω, ±(0.8% of rdg + 3 dgts)
◆ Diode: Test voltage 1.6V DC
◆ With continuity buzzer, autorange, auto power-off, data hold
◆ Weight: 240g
◆ CE certified
-
Axis RF Field Strength Meter
◆ This Axis RF Field Strength Meter is your best tool in measuring and monitoring radio frequency and capable of measuring the frequency range of 50MHz-3.5GHz.
◆ Applications:
- Measurement of RF power for transmitters.
- Measurement of RF electromagnetic wave field strength
- Measurement of radiation power density in mobile phone base station antenna
- Spy camera, wireless bug finder
- Wireless communication (CW, TDMA, GSM, DECT) applications
- Wireless LAN (Wi-Fi) detection, installation
- Cellular /Cordless phone radiation safety level
- Microwave oven leakage detection
- For personal living environment EMF safety
◆ RF range: 38mV to 20V/M
◆ Frequency range: 50MHz to 3.5GHz.
◆ Sensors: Triple Axis (X, Y, Z)
◆ Manual data memory (Max & AVG) records.
◆ Display type: Liquid-crystal (LCD), 4-1/2 digits maximum reading 19999
◆ Measurement method: Digital, triaxial measurement
◆ Directional characteristic: Isotropic, triaxial
◆ Measurement range selection: one continuous range
◆ Display resolution:0. 1mV/m, 0.1μA/m, 0.001μW/m2, 0.001μW/cm2
◆ Setting time: typically 1.5s (0 to 90% measurement value)
◆ Sample rate: 1.5 times per second
◆ Audible alarm: Buzzer
◆ Units: mV/m, V/m, μA/m, mA/m, μW/m2, mW/m2, μW/cm2
◆ Display value: Instantaneous measured value, maximum value, average value, or maximum average value
◆ Alarm function: adjustable threshold with ON / OFF
◆ Calibration factor CAL: adjustable
◆ Manual data memory and read storage:200 data sets
◆ Batteries: 9V NEDA 1604, IEC 6F22 or JIS 006P
◆ Battery life: Approximate 15 hours
◆ Auto power off: Default time 15 minutes. Adjustable threshold 0~99 minutes
◆ Operating temperature range: 0°C to + 50°C
◆ Operating humidity range: 25% to 75 % RH
◆ Storage temperatures range: -10°C to +60°C
◆ Storage humidity range: 0% to 80% RH
◆ Dimensions: 60(L)*60(W)*195(H) mm
◆ Weight (including battery): Approx.200g
◆ Accessories: User's manual, 9V battery, Carrying case
-
Light Meter
◆ 3? digits LCD with maximum reading 2000
◆ Overload indication
◆ Low battery indication
◆ According to JISC1609:1993 and CNS 5119 general A class specifications
◆ Spectral response close to CIE luminous spectral efficiency
◆ Measuring intensities of illumination in unit of Lux or Foot-candle
◆ Measuring lights source include all visible range
◆ Cosine angular corrected
◆ This Light Meter can be used in warehouses, factories, office buildings, restaurants, schools, library, hospitals, photographic,video, parking garages, museums, art galleries, stadiums, building security.
-
Anemometer TM-412
Model: TM-412A
Measurement Range of Wind Speed:
m / s: 0.4 ~ 35
km / hr: 1.5 ~ 125
mph: 0.9~75
Beaufort: 1 ~ 11
ft / min: 79 ~ 6800
kts: 0.8 ~ 65
Measurement Range of Wind Volume: CMM/CFM 0 ~ 9999
Measurement Range of Temperature: -20℃ ~ 60℃(-4°F ~ 140°F)
Size of Probe: 135x67x31mm
Size of Anemometer: 140x65x38mm
◆ Suitable to measure wind speed for ventilation system
◆ Split fan, can monitor and read at the same time
◆ Big screen allows easy reading
◆ Memories up to 99 records
◆ Fan, diameter at 45mm, with 4 blades
◆ With Max., Min. and average value, and "hold" function
◆ Auto shut down function, low battery reminder
◆ Memory call out function, LED light for reading in dark
◆ Comes with: Instruction leaflet, storage bag and detetive probe
-
Digital Clamp Meter TM-1015
◆ 3 3/4 digits display with maximum reading of 3999
◆ With auto power-off, data hold, max./min data set
◆ Maximum conductor size 30mm
◆ Dimension: 205 x 64 x 39mm
◆ AC / DC current: 40A, 400A
◆ AC / DC Voltage: 400mV, 4V, 40V, 400V, 600V
◆ Resistance: 400Ω, 4KΩ, 400KΩ, 4MΩ, 40MΩ
-
AC-HVAC Clamp Meter
◆ CAT III 600V
◆ 3-3/4 digit LCD Backlit Display, with Analog Bargraph.
◆ Display Counts: 4000.
◆ Auto Ranging.
◆ AC/DC current: 0.1μA to 4000μA. (using test leads)
◆ Maximum Current: 400 Amps
◆ AC Current: 0.01A to 400A (using jaw measurement)
◆ AC Voltage Range: 0.1mV to 600V, ±(1.0% of rdg + 3 dgts)
◆ DC Voltage Range: 0.1mV to 600V, ±(0.8% of rdg + 2 dgts)
◆ Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity, Capacitance, and Temperature.
◆ Maximum Conductor Size: 30mm
◆ Continuity test below 40 ohms, buzzer will sound.
◆ Auto Power off
◆ Data Hold: Yes
◆ Double injection outer case
◆ Capacitance: 10pF to 4mF
◆ Temperature (Type 'K'): -50°C to 1200°C
◆ Power Supply: 2 1.5V type 'AAA' batteries
◆ Resistance: 0.1 ohm to 40 megohms ±(0.8% + 2 dgts)
◆ Dimensions: 205mm (L) x 64mm (W) x 39MM (D)
◆ Weight: 280g (including batteries)
-
Sound Level Meter TM-102
◆ IEC 61672, Type II
◆ Auto Ranging
◆ LO, MED, HI ranges
◆ 3 1/2 digits LCD display with maximum reading of 2000, Baclit LCD
◆ Test ranges: 30~130dB (LO: 30~80dB, MED: 50~100dB, HI: 80~130dB)
◆ Accuracy: +/- 1.5dB(ref 94dB @1KHz)
◆ Resolution: 0.1dB
◆ Microphone: 1/2 inch Electret condenser microphone
◆ Frequency Weighting: A, C
◆ Time Weighting: FAST,SLOW
◆ Auto Ranging, Auto Power Off, Data hold, Max/Min
◆ Dynamic Range: 50dB
◆ Frequency Range: 30Hz~8KHz
◆ Size: 200x55x38mm
◆ Weight (including battery): 290g